ekorRPS-TCP

Power Networks Protection

ekorRPS-TCP

Multifunctional protection unit, it acts as an independent protection, measurement and control unit or integrated in a protection control system.

The services offered by this unit satisfy the most demanding automation and control systems required by modern substations.

Technical Features:

 

  • Protection Functions:
    • Over current
      • Phase over current (3X50/51)
      • Earth faults (50N/51N)
      • Sensitive earth faults (50Ns/51Ns)
      • Directional phase over current (3X67)
      • Directional neutral over current (67N)
      • Directional isolated neutral over current (67NA)
      • Current unbalance protection (46-46FA)
      • Thermal image (49)
      • Cold Load Pickup
      • Voltage-restrained Time over current (51V)
      • Voltage regulation (50CSC)
      • Breaker failure (50BF)
    • Undercurrent (37)
    • Voltage:
      • Over voltage protection (59)
      • Under voltage protection (27)
      • Zero-sequence overvoltage (59N)
      • Synchronism (25)
      • Voltage unbalance (47)
    • Frequency
      • Maximum and minimum frequency (81M/m)
      • Frequency rate (81R)
    • Power
      • Max/min active power
      • Max/min apparent power
      • Active/reactive power inversion
  • Logic functions and automation
    • Recloser (79)
    • Switch monitoring
    • Trip and closing circuit monitoring
    • Synchronism checking
    • Configurable inputs/outputs
    • Programable logic
    • Others
      • Protection status self-checking
      • Configuration up to 6 setting tables
  • Metering
    • Phase, neutral and sensitive neutral current metering
    • Single and compound voltage metering
    • Active, reactive and apparent power metering
    • Active and reactive energy metering
    • Power factor metering
    • Maximum current indicator
    • Negative sequence metering (I2/I1) as a %
    • Total Harmonic Distortion (THD)
  • Data Acquisition
    • Event chronological logging
    • Fault chronological logging
    • Log of maximum and minimum meterings
    • Oscilloperturbograph
  • Communications:
    • IEC 60870-5-103
    • IEC 60870-5-101
    • ModBUS RTU
    • DNP3.0
    • PROCOME
    • HARRIS
    • Ports: RS485 and O.F.

 

Product catalogues downloads

.pdfekorRPS-TCP unidad de protección multifuncional para subestación de distribución primaria (372.11 kB)
CA418ES1101
Castellano
.pdfekorRPS-TCP multifunctional protection unit for primary distribution substation (259.99 kB)
CA418GB1101
English



Protection
MV client supply ekorRPG ekorRPT Protections for Switching Substations and Industrial Clients ekorRPS ekorRPGci ekorRPTci Protection for rural Transformer Substations (CTR) ekorRPT-K Engine-Generator Protection Unit ekorUPG Substation Protection ekorRPS-TCP
Automation and Remote Control
Remote Control ekorUCT ekorCCP ekorRCI Compact cubicle with integrated automation equipment Automatic Transfers ekorSTP ekorCCP ekorRTK Fault Detection ekorRCI Voltage Presence Acoustic Alarm System ekorSAS Secondary Switching Points Secondary Switching Points
Telemanagement & Communicattion
Telemanagement ekorGID
Control Area
Dispatching Centre
Software
ekorSOFT
Services
Protection, Control and Automation
ekorSYS applications
ekorSYS applications


asesoramiento
Do you need advice?

If you need help please fill in the following form.

Advice form
Grupo Ormazabal
© www.ormazabal.com